Tel : 0-2680-5800

Cable name : MEDIUM VOLTAGE CROSS-LINKED POLYETHYLENE CABLE

Cable Structure : COPPER CONDUCTOR THREE CORES WITH COPPER TAPE SHIELD
Conductor :  Compact round stranded copper.
Conductor Sizes : 35 – 400 mm2
Insulation : Cross-linked polyethylene.
Application : Preferably used for urban networks.Exposed in aerial, direct burial,
conduit, open tray and underground duct installation.
Continue reading “MXLP-CTS 3-Core”

Cable name :  PHELPS DODGE CABLE TYPE PdsolarTec Photovoltaic (PV) Cable Type H1Z2Z2-K

Cable Structure:   1.5(1.8) kV DC XLPE INSULATED AND XLPE SHEATHED,SINGLE CORe
Conductor : Flexible tinned copper conductor class5
Conductor Sizes: 2.5 up to 240 sq.mm.
Insulation : Cross-linked polyethylene (XLPE)
Outer Sheath: Cross linked polyethylene (XLPE)
Application : Photovoltaic (PV) Cables cables for interconnecting at DC side of photovoltaic systems such as solar panel arrays. The cables are suitable for permanent use both indoor and outdoor, for free movable, free hanging and fixed installation in conduits,in trunks, in/under plaster as well as in appliances.

Price List

Continue reading “Photovoltaic (PV) Cable Type H1Z2Z2-K”

Cable name : ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED

Cable Structure : POLYETHYLENE INSULATED
Conductor :  Compact stranded hard drawn Aluminium wire.
Conductor Sizes : 35 – 240 mm2
Insulation : Track resistant cross-linked polyethylene (Black)
Application : For used in primary aerial cable on pole.
Continue reading “SAC 23,35 kV”

Cable name : MEDIUM VOLTAGE CROSS-LINKED POLYETHYLENE CABLE

Cable Structure : COPPER CONDUCTOR WITH COPPER TAPE SHIELD
Conductor :  Compact round stranded copper.
Conductor Sizes : 35 – 1200 mm2
Insulation : Cross-linked polyethylene.
Application : Preferably used for urban networks.Exposed in aerial, direct burial,
conduit, open tray and underground duct installation.
Continue reading “MXLP-CTS”

Cable name : ALUMINIUM STRANDED CONDUCTOR CROSS-LINKED

Cable Structure : POLYETHYLENE INSULATED
Conductor :  Compact stranded hard drawn Aluminium wire.
Conductor Sizes : 35 – 185 mm2
Insulation : Track resistant cross-linked polyethylene (Black)
Application : For used in primary aerial cable on pole.
Continue reading “SAC”

Cable name : MEDIUM VOLTAGE CROSS-LINKED POLYETHYLENE CABLE

Cable Structure : COPPER CONDUCTOR WITH COPPER WIRE SHIELD
Conductor :  Compact round stranded copper.
Conductor Sizes : 35 – 1200 mm2
Insulation : Cross-linked polyethylene.
Application : Preferably used for urban networks. Exposed in aerial, direct burial,
conduit, open tray and underground duct installation.
Continue reading “MXLP-CWS”

Cable name : MEDIUM VOLTAGE CROSS-LINKED POLYETHYLENE CABLE

Cable Structure : 3.6/6 (7.2) kV COPPER CONDUCTOR THREE CORES WITH STEEL WIRE ARMOUR
Conductor :  Compact round stranded copper.
Conductor Sizes : 35 -400 mm2
Insulation : Cross-linked polyethylene.
Application : Preferably used for urban networks.Exposed in aerial, direct burial,
conduit, open tray and underground duct installation.
Continue reading “MXLP-SWA 3-Core”

Cable name : MEDIUM VOLTAGE CROSS-LINKED POLYETHYLENE CABLE

Cable Structure : COPPER CONDUCTOR THREE CORES WITH STEEL WIRE ARMOUR
Conductor :  Compact round stranded copper.
Conductor Sizes : 35 -400 mm2
Insulation : Cross-linked polyethylene.
Application : Preferably used for urban networks.Exposed in aerial, direct burial,
conduit, open tray and underground duct installation.
Continue reading “MXLP-LS-SWA 3-Core”

Cable name : MEDIUM VOLTAGE CROSS-LINKED POLYETHYLENE CABLE

Cable Structure : COPPER CONDUCTOR WITH DOUBLE ALUMINIUM TAPE ARMOUR
Conductor :  Compact round stranded copper.
Conductor Sizes : 35 – 1200 mm2
Insulation : Cross-linked polyethylene.
Application : Preferably used for urban networks. Exposed in aerial, direct burial,
conduit, open tray and underground duct installation.
Continue reading “MXLP-DATA”

Cable name : MEDIUM VOLTAGE CROSS-LINKED POLYETHYLENE CABLE

Cable Structure : COPPER CONDUCTOR THREE CORES WITH DOUBLE STEEL TAPE ARMOUR
Conductor :  Compact round stranded copper.
Conductor Sizes : 35 -400 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks. Exposed in aerial, direct burial,
conduit, open tray and underground duct installation.
Continue reading “MXLP-DSTA 3-Core”

Cable name : MEDIUM VOLTAGE CROSS-LINKED POLYETHYLENE CABLE

Cable Structure : COPPER CONDUCTOR WITH ALUMINIUM WIRE ARMOUR
Conductor :  Compact round stranded copper
Conductor Sizes : 35 – 1200 mm2
Insulation : Cross-linked polyethylene.
Application : Preferably used for urban networks.Exposed in aerial, direct burial,
conduit, open tray and underground duct installation.
Continue reading “MXLP-AWA”

Cable name : HXLP-CWS-LAT COPPER CONDUCTOR WITH COPPER WIRE SHIELD

Cable Structure : AND LAMINATED ALUMINIUM TAPE, RIBBED OVERSHEATH
TIS 2202-2547 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -1200 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-CWS-LAT 69”

Cable name : HXLP-CWS-LAT COPPER CONDUCTOR WITH COPPER WIRE SHIELD

Cable Structure : AND LAMINATED ALUMINIUM TAPE
IEC 60840 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene.
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-CWS-LAT”

Cable name : HXLP-CWS-LS COPPER CONDUCTOR WITH COPPER WIRE SHIELD

Cable Structure : IEC 60840 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-CWS-LS”

Cable name : HXLP-LS COPPER

Cable Structure : CONDUCTOR WITH LEAD SHEATH IEC 60840 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-LS”

Cable name : HXLP-CAS COPPER CONDUCTOR WITH CORRUGATED

Cable Structure : ALUMINIUM SHEATH IEC 60840 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-CAS”

Cable name : HXLP-CCS

Cable Structure : IEC 60840 STANDARD CONDUCTOR WITH CORRUGATED COPPER SHEATH
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
 trays and direct burial in ground.
Continue reading “HXLP-CCS”

Cable name : EHXLP-CWS-LAT

Cable Structure : COPPER CONDUCTOR WITH COPPER WIRE SHIELD
AND LAMINATED ALUMINIUM TAPE IEC 62067 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “EHXLP-CWS-LAT”

Cable name : EHXLP-CWS-LS

Cable Structure : COPPER CONDUCTOR WITH COPPER WIRE SHIELD
AND LEAD SHEATH IEC 62067 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “EHXLP-CWS-LS”

Cable name : EHXLP-LS

Cable Structure : COPPER CONDUCTOR WITH LEAD SHEATH
IEC 62067 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “EHXLP-LS”

We use cookies to improve performance. and good experience in using your website You can study the details at Privacy Policy and you can manage your own privacy by clicking Setting

Privacy Preferences

You can set your cookies preferences on our website except the necessity cookies.

Allow All
Manage Consent Preferences
  • Necessity Cookies
    Always Active

    These cookies are necessary for website to operate. To ensure that you can use and visit the website normally, you cannot turn off these cookies on our website.

  • Functionality Cookies

    Allow Functionality Cookies to remember your setting on the platform e.g. username, language, fonts, and platform.

  • Performance Cookies

    Allow Performance Cookies to analyse the performance of each part of our website for improvement purpose.

  • Advertising Cookies

    Allow the website to use Advertising Cookies for increasing the product or service presentation be more accurate

Save your setting