Cable name : HXLP-CWS-LAT COPPER CONDUCTOR WITH COPPER WIRE SHIELD

Cable Structure : AND LAMINATED ALUMINIUM TAPE, RIBBED OVERSHEATH
TIS 2202-2547 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -1200 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-CWS-LAT 69”

Cable name : HXLP-CWS-LAT COPPER CONDUCTOR WITH COPPER WIRE SHIELD

Cable Structure : AND LAMINATED ALUMINIUM TAPE
IEC 60840 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene.
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-CWS-LAT”

Cable name : HXLP-CWS-LS COPPER CONDUCTOR WITH COPPER WIRE SHIELD

Cable Structure : IEC 60840 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-CWS-LS”

Cable name : HXLP-LS COPPER

Cable Structure : CONDUCTOR WITH LEAD SHEATH IEC 60840 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-LS”

Cable name : HXLP-CAS COPPER CONDUCTOR WITH CORRUGATED

Cable Structure : ALUMINIUM SHEATH IEC 60840 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “HXLP-CAS”

Cable name : HXLP-CCS

Cable Structure : IEC 60840 STANDARD CONDUCTOR WITH CORRUGATED COPPER SHEATH
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 150 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
 trays and direct burial in ground.
Continue reading “HXLP-CCS”

Cable name : EHXLP-CWS-LAT

Cable Structure : COPPER CONDUCTOR WITH COPPER WIRE SHIELD
AND LAMINATED ALUMINIUM TAPE IEC 62067 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “EHXLP-CWS-LAT”

Cable name : EHXLP-CWS-LS

Cable Structure : COPPER CONDUCTOR WITH COPPER WIRE SHIELD
AND LEAD SHEATH IEC 62067 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “EHXLP-CWS-LS”

Cable name : EHXLP-LS

Cable Structure : COPPER CONDUCTOR WITH LEAD SHEATH
IEC 62067 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “EHXLP-LS”

Cable name : EHXLP-CAS

Cable Structure : COPPER CONDUCTOR WITH CORRUGATED ALUMINIUM SHEATH
IEC 62067 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “EHXLP-CAS”

Cable name : EHXLP-CCS

Cable Structure : COPPER CONDUCTOR WITH CORRUGATED COPPER SHEATH
IEC 62067 STANDARD
Conductor :  Round compact stranded or Milliken conductor
Conductor Sizes : 400 -2500 mm2
Insulation : Cross-linked polyethylene
Application : Preferably used for urban networks.Suitable for use in duct,
trays and direct burial in ground.
Continue reading “EHXLP-CCS”